id crossShipFlag dateResolved issueId lineNum note productId productSubId qty resolutionId returnFlag rmaId shipFlag typeId uomId vendorId vendorRMA
27 _binary    3 1 Disposition Notes: After evaluation it was confirmed that the 2 cables returned had leaks. Immediate Correction: Re-pot cables from the back side to plug up any microscopic voids that create the leaks. Proposed Preventive Action: Innofiber has proposed the presence of the bead around the bundle inside the shell. CAPA 000413 has been opened to track the changes made. all cables are currently being tested twice, and pictures are being taken to provide evidence of no leaks. 3   1.0   _binary 16 _binary  40 1    