{"database": "fishbowl_archive", "table": "rmaitem", "rows": [[44, "_binary \u0000", null, 3, 1, "Disposition:  After evaluation of the 17 cables returned off RGA 2496 Qty of 17 we have confirmed that 16 pcs failed the leak test and 1 pc passed.\n\nImmediate Correction:  We will rework the 16 pcs and return the 1 cable that is good with no rework performed.\n\nProposed Preventive Action:  \nDuring review of the validation report, it was confirmed that the cables were validated to withstand a single pressure test at 3.9 PSI.  However, testing performed at Innofiber and the customer's facility includes:\n\nA.)   A single test at 8 PSI which is more than double the validted pressure.\n\nB.)  Multiple test at 4 PSI, which also exceed the validated conditions.\n\nInnofiber considers testing at 8 PSI , for 30 seconds to be destructive in nature and this has been communicated to ISI .  As such, no CAPA will be opened for this issue.\n\nWhile the conditions fall outside the scope of warranty coverage, Innofiber is willing to evaluate and repare cables when possible.  Please note:\n\nNo- nonconformance reports will be accepted for cables returned due to leaks resulting from over-pressure testing.\n\nRepairs will be performed at a cost quoted by our sales team,  based on the extent of damage and feasibility of repair.", 3, null, 17.0, null, "_binary \u0000", 26, "_binary \u0001", 40, 1, null, ""]], "columns": ["id", "crossShipFlag", "dateResolved", "issueId", "lineNum", "note", "productId", "productSubId", "qty", "resolutionId", "returnFlag", "rmaId", "shipFlag", "typeId", "uomId", "vendorId", "vendorRMA"], "primary_keys": ["id"], "primary_key_values": ["44"], "units": {}, "query_ms": 1.5489899669773877}